- 7 -
2. PROTOCOL ID : 3, 4
1) Maker :
PANASONIC HALF(3) / FULL(4)
2)DipSwitch:
Set 5,6,7,8 pin of SW501.(Protocol Select)
PANASONIC
HALF
Duplex
ON
OFF
SW501
12
34 5 6 78
PANASONIC
FULL
Duplex
ON
OFF
SW501
12
34 5 6 78
SW501 1~2 : RS-485 Termination (Refer to SCC-641/643 Owner's Instructions)
3~4 : DM Sprite2 Only 19200 bps.
Baud Rate SW501-3 SW501-4
19200BPS OFF OFF
9600BPS ON OFF
4800BPS OFF ON
2400BPS ON ON
3) Function 1
PANASONIC WV-CU161 Controller SCC-641/643
1 CAM ADDR CAMERA ADDR Select
2 Pan/Tilt/Zoom/Focus/Iris Pan/Tilt/Zoom/Focus/Iris
3#(1~54)
→
PRESET SET Go to Preset (1 ~ 54)
4
CAMERA SETUP or
#(55)
→
PRESET SET
Camera Menu On/Off
5
PRESET SET or
#
→
PRESET SET Holding Cam setup(program) or
#(56)
→
PRESET SET
Menu Mode : Enter Key
6#(58)
→
PRESET SET Autopan 1
7#(59)
→
PRESET SET Scan 1
8#(60)
→
PRESET SET Alarm Reset
6 HOME ESC Menu Mode :
※₁
7#(61)
→
PRESET SET Pattern 1
8#(62)
→
PRESET SET Pattern 2
9#(63)
→
PRESET SET Pattern 3
10 #(64)
→
PRESET SET Camera Reset
11 #(1)
→
AUTO Auto Pan
12 #(2)
→
AUTO Scan
13 #(3)
→
AUTO Alarm Reset