2This product has been determined to be in compliance with the Low Voltage Directive (2006/95/EC), and the Electromagnetic Compatibility Directive (20
11ENGLISHPress the button to turn on the air conditioner.Press the button to set the operating mode.t &BDIUJNFZPVQSFTTUIFMode button, th
12Adjusting the air ow directionAir ow can be directed to your desired position.Turbo function will be helpful to cool your room quickly and e ec
ENGLISH13modeFor a comfortable sleep, the air conditioner will operate it Fall asleep Z Sound sleep Z Wake up from mode.1. Press the button on the
14Setting the On/O timerYou can set the air conditioner to turn on/o automatically at desired time. Setting On timer while the air conditioner is
ENGLISH15Combining On Timer and O TimerIf the air conditioner is on If the air conditioner is o Preset time on On timer is shorter than O timer&a
16Auto clean function will prevent from growing mold by eliminating the moisture inside of the indoor unit. Your indoor unit evaporates the moisture i
ENGLISH17Cleaning the air conditionerCleaning the indoor unitCleaning the outdoor unit heat exchangerOpening the panelXWipe the surface of the unit wi
18Cleaning the air conditionerRemoving the Air lterGrab the handle and lift it up. Then, pull the Air lter towards you and slide it down. Air lt
ENGLISH19Maintaining the air conditionerIf the air conditioner will not be used for an extended period of time, dry the air conditioner to maintain it
20TroubleshootingRefer to the following chart if the air conditioner operates abnormally. This may save time and unnecessary expenses.PROBLEM SOLUTION
ENGLISH3Safety precautionsBefore using your new air conditioner, please read this manual thoroughly to ensure that you know how to safely and ecientl
21ENGLISHPROBLEM SOLUTIONError is indicated. t When an indoor unit indicator blinks, contact the nearest service center.Noise is generated. t %FQF
22Carefully follow the precautions listed below because they are essential to guarantee the safety of the equipment.t"MXBZTEJTDPOOFDUUIFBJS
ENGLISH23Installing the unit*.1035"/58IFOJOTUBMMJOHUIFVOJUBMXBZTSFNFNCFSUPDPOOFDUöSTUUIFSFGSJHFSBOUUVCFTUIFOUIFFMFDUSJDBMMJOF
24Outdoor UnitXWhere it is not exposed to strong windXWell ventilated and dustless placesXOut of the direct sunlight and rainXWhere neighbors are not
25ENGLISHSpace Requirements for Outdoor UnitWhen installing 1 outdoor unitWhen installing more than 1 outdoor unit300 or moreX When the air outlet is
26Choosing the installation location6OJUNNX When the upper part of the outdoor unit and the air outlet is opposite the wallX When the walls are b
ENGLISH27t .BLFTVSFUPESJMMPOMZPOFhole after choosing the direction of the pipe.Fixing the installation plateThe following connection accessori
28Wall<20mmPlastic AnchorFixing the installation plate2. Fix the indoor unit.If you x the indoor unit on a wall (1) Fix the installation plate to
ENGLISH292 . Open the front grille.3 . Remove the screw securing the connector cover.4 . Pass the assembly cable through the rear of the indoor uni
30Installing and connecting the assembly pipe of the indoor unit1. Cut out the appropriate knock-out piece (A, B, C) on the rear of the indoor unit un
4Safety precautionsFOR POWER SUPPLYWARNINGRemove all foreign substances such as dust or water from the power plug terminals and contact points using a
ENGLISH31Purging the indoor unit1. Unscrew the caps at the end of each pipe. XAll inert gas exhausts from the indoor unit. 1. Make sure that you hav
32Cutting or extending the pipeOuter Diameter 5PSRVFLHGtDNø6.35 mm 140~170ø9.52 mm 250~280ø12.70 mm 380~420ø15.88 mm 440~480ø19.05 mm 990~1210ø22.2
ENGLISH33t 5IFIPTFXJMMCFöYFEQFSNBOFOUMZJOUPQPTJUJPOBGUFSöOJTIJOHUIFJOTUBMMBUJPOBOEUIFHBTMFBLUFTUSFGFSUPQBHF37~38 for further de
34Installing and connecting the drain hose of the outdoor unitFrameGroundEstimated snow fallSnow-proof hoodBottom surface of outdoor unitDrain hoseDra
ENGLISH353. Connect the charging hose of the low-pressure side of manifold gauge to a gas service port as seen in the picture.4. Open the valve of the
36Purging the connected pipesRefrigerant type GWP valueR410A 1975KGWP=Global Warming PotentialIndoor unitOutdoor unit=( ) kg=( ) kg+= ( ) kgCont
ENGLISH37Performing the gas leak testsCDABMake sure to check for gas leaks before completing the installation process (connecting the assembly pipe an
38Fixing the indoor unit in placeInsulationPipes'X' mmRubber leg'Y' mmPerform the following work on the area where gas leak test w
ENGLISH39Final Check and Trial OperationTo complete the installation, perform the following checks and tests to ensure that the air conditioner operat
40 Items to prepare (compressor and insulation tape should be prepared by an installation technician.)1. As shown in the gure, peel o the shiel
5ENGLISHFOR USINGWARNINGDo not place an object near the outdoor unit that allows children to climb onto the machine.XThis may result in children serio
ENGLISH41Sub PCB installation(optional)(Wried remote controller, central remote controller etc.)1. Turn the power o and take o the front panel of th
QUESTIONS OR COMMENTS?COUNTRY CALL OR VISIT US ONLINE AT ALBANIA 42 27 5755AUSTRIA0810 - SAMSUNG (7267864, € 0.07/min)www.samsung.comBELGIUM 02-201-
AQV07P7 SeriesAQV09P7 SeriesAQV12P7 SeriesAQV18P7 SeriesAQV24P7 SeriesAir Conditioneruser & installation manualimagine the possibilitiesThank you
6Operation rangesThe table below indicates the temperature and humidity ranges the air conditioner can be operated within. Refer to the table for eci
ENGLISH7Main partsDisplay indicatorTimer/Auto clean indicatorOperation indicatorPower buttonRemote controller receiverYour air conditioner may slight
8Checking the remote controllerRemote controller buttonst 1PJOUUIFSFNPUFDPOUSPMMFSUPXBSETUIFSFNPUFDPOUSPMMFSSFDFJWFSPGUIFJOEPPSVOJUt 8
9ENGLISHRemote controller displayt 5IFTJHOBMNBZOPUCFSFDFJWFEXFMMPGFMFDUSPOJDMJHIUJOHTUZMFøVPSFTDFOUMBNQTTVDIBTJOWFSUFSøVPSFTDFOUM
10Basic operation is an operation mode that can be selected by pressing the Mode button. AutoIn Auto mode, the air conditioner will automatically set
Komentarze do niniejszej Instrukcji