AVXC1@@_IM_E_29824-1_4.14.09.indd 1 2009-4-14 9:48:08

Strona 2 - Contents

E-10Selecting the Installation Location (Continued)No. Name DescriptionLiquid pipe connection045/056ø6.35 (1/4”)071/090/112/128/140ø9.52 (3

Strona 3 - Safety Precautions

E-11Selecting the Installation Location (Continued)AVXCMUnit : mmNo. Name DescriptionLiquid pipe connectionø6.35 (1/4")Gas pipe connectionø12

Strona 4

E-12Indoor Unit InstallationConcreteSuspension bolt(3/8" or M10)Hole in anchorHole in plugInsertIt is recommended to install the Y-joint before i

Strona 5 - Accessories

E-13Indoor Unit Installation4Screw eight nuts to the suspension bolts making space for hanging theindoor unit. CAUTION You must insta

Strona 6 - Indoor Unit

E-14Purging the Unit Gas refrigerant portLiquid refrigerant port The designs and shape are subject to change according to the model.From factory the

Strona 7 - Dimension of the indoor unit

E-15Connecting the Refrigerant PipeRefrigerant oilTorque wrenchFlare nutUnionSpannerThere are two refrigerant pipes of differing diameters: A sma

Strona 8

E-16Cutting/Flaring the Pipes1Make sure that you prepared the required tools. (pipe cutter, reamer, flaring tool and pipe holder)2If you want to shor

Strona 9

E-17Performing Leak Test & Insulation The designs and shape are subject to change according to the model.Leak checkLEAK TEST WITH NITROGEN (befo

Strona 10 - AVXC4112/128/140

E-18Performing Leak Test & Insulation (Continued) 5Select the insulation of the refrigerant pipe.  Insulate the gas side and liquid side pipe

Strona 11

E-19 Drain pipe and Drain Hose InstallationInsulation drainpipeBandBandFlexible hoseDrain hose portDrainpipeAdhesivesInsulation cover bandInsulation

Strona 12 - Indoor Unit Installation

E-2ContentsSafety Precautions ... 3Accessories ...

Strona 13

E-20Drain pipe and Drain Hose Installation (Continued)Drainpipe Connection 1The drain pipe should be installed within 100mm from the flexible hose, l

Strona 14 - Purging the Unit

E-21Drain pipe and Drain Hose Installation (Continued)Centralized Drainage 1Install main air vent at the front of the farthest indoor unit from the ma

Strona 15

E-22Wiring WorkSilver solderN LN LN LN LIndoor Unit 1Outdoor UnitIndoor Unit 2 Indoor Unit 3Wired Remote Control220-240V~ ELB : Essential Installati

Strona 16 - Cutting/Flaring the Pipes

E-23Wiring WorkRating currentUnit Model Rating currentAVXC10220280360.18A0.20A0.23AAVXCS0220280360.20A0.23A0.25AAVXC2

Strona 17 - Insulation

E-24Wiring Work (Continued)  Select the power cable in accordance with relevant local and national regulations.  Wire size must comply with local a

Strona 18

E-25Indoor Unit Setting1 Before installing the indoor unit, assign an address to the indoor unit according to the air conditioning system plan.2 The

Strona 19 - Band(Not supplied)

E-26Additional FunctionsK5 K6 K7 K8K1 K2 K3 K4K9K10K11K12No. Function ON OFFSW07K9Indoor Expansion Valve For Heating Stop Fix 80 step 0 or 80 stepK10

Strona 20 - Centralized Drainage

E-27Final Checks and User TipsTo complete the installation, perform the following checks and tests to ensure that the air conditioner operates correct

Strona 21 -

E-28Troubleshooting LED DisplayLED Display on the receiver & display unit Abnormal conditionsIndicatorsOperatingGreen RedPower resetX X X

Strona 22 - Wiring Work

E-29Troubleshooting LED Display Abnormal conditionsIndicatorsOperatingGreen Red Self-diagnostic error (including the indoor unit not detected)

Strona 23

E-3(Carefully follow the precautions listed below because they are essential to guarantee the safety of the equipment.)WARNING• Always disconnect the

Strona 24 - Wiring Work (Continued)

"EEE Yönetmeliğine Uygundur" "This EEE is compliant with RoHS"AVXC1@@_IM_E_29824-1_5.05.09.indd 30 2009-5-12 8:46:05

Strona 25 - Indoor Unit Setting

INSTALLATION MANUALCassette Type Series1 way cassette : AVXC1AVXCS(Slim)2 way cassette : AVXC24 way cassette : AVXC4 AVXCM(mini)DB98-298

Strona 26 - Additional Functions

E-4  Make sure that you earth the cables. - Do not connect the earth wire to the gas pipe, water pipe, lighting rod or telephone wire. If earthin

Strona 27 - Final Checks and User Tips

E-5AccessoriesThe following accessories are supplied with the indoor unit. The type and quantity may differ depending on the specifications.AVXC1/AV

Strona 28 - Troubleshooting

E-6Indoor Unit There must be no obstacles near the air inlet and outlet. Install the indoor unit on a ceiling that can support its weight. Ma

Strona 29

E-7Selecting the Installation LocationDimension of the indoor unitAVXC1Unit : mm No. Name DescriptionLiquid pipe connectionø6.35 (1/4”)Gas pipe

Strona 30

E-8Selecting the Installation Location (Continued)Dimension of the indoor unitUnit : mmNo. Name DescriptionLiquid pipe connection ø6.35 (1/4”)Gas pi

Strona 31 - INSTALLATION

E-9Selecting the Installation Location (Continued)AVXC2Unit : mm 890919103011725230136.549318015772.5650575No. Name DescriptionLiquid pipe connect