Start
5 minutes after
compressor off?
Check it after 5 minutes
Freezer sensor is
OK?
Replace sensor
Check detector &
replace PCB
Main PCB temperature
detector is OK?
Check wiring
Is compressor
operated by forse?
MICOM pin24
output is HIGH ?
IC07 pin10 output
is LOW ?
Comp relay is OK?
Connector CON 8, 10
contects are OK?
Comp ass y is OK?
Check wires connection
Replace comp
Check connector
Reference 2
Reference 7
Reference 6
(Page. 40)
(Page. 41)
(Page. 38)
Replace IC07
Replace relay
Replace MICOM
and PCB
N
Y
Y
Y
Y
Y
Y
Y
N
N
N
N
N
N
N
N
Y
Y
Samsung Electronics 29
2) Compressor does not run
1. Compressor does not operate in 5 minutes after power ON and compressor OFF.
2. Compressor does not run during defrosting.
3.
Compressor does not run because low temperature is detected if freezer sensor is not connected.