Samsung SR-L628EV Dokumentacja

Przeglądaj online lub pobierz Dokumentacja dla Nie Samsung SR-L628EV. Samsung SR-L628EV Product specifications Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 81
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 0
REFRIGERATOR
Model : SR-L677EV
SR-L679EV
SR-L627EV
SR-L629EV
REFRIGERATOR CONTENTS
1. Precautions
2. Product Specifications
3. Electrical Part Specifications & Standard
4. Circuit Diagram
5. Functions & Operating Instruction
6. Circuit Descriptions
7. Trouble shooting
8. Exploed View
9. Disassembly & Assembly
10. PCB Circuit Diagram
11. PCB Parts List
12. Specifications of Main Components
SR-L677EV
SR-L679EV
SR-L627EV
SR-L629EV
GREEN
Przeglądanie stron 0
1 2 3 4 5 6 ... 80 81

Podsumowanie treści

Strona 1 - REFRIGERATOR

REFRIGERATORModel : SR-L677EVSR-L679EVSR-L627EVSR-L629EVREFRIGERATOR CONTENTS1. Precautions2. Product Specifications3. Electrical Part Specifications

Strona 2 - 1. Precautions

5-4. Cool Air Circulation10

Strona 3 - 2. Product Specifications

2. Temperature control function1) Temperature selection of freezer compartment❈ After the initial key selection, it displays the notch which is presen

Strona 4 - (MK172C-L2U)

3) Quick freeze3-1) Press the on/off buttons of Quick Freeze so that the lamp of Quick Freeze is light up andoff and then it operates it’s function au

Strona 5 - 4. Circuit Diagram

5) Sabbath function5-1) It will turn to sabbath function if you press freezer and refrigerator temperatune buttontogether for 5 seconds.5-2) When turn

Strona 6 - MAIN PCB

5. Test function❈ Test function is for the test of PCB, product, official inspection and ability of SVC.❈ When s/w test is chosen and tested the produ

Strona 7 - 5-1. Product Dimension

❈ Exhibition mode1. When you press quick freeze button and freezer temp. button together the operation changesinto exhibition mode.2. In exhibition mo

Strona 8 - • Tray disassembly

12345No• Open faulty • Short faulty• Open faulty • Short faulty• Open faulty • Short faulty• Open faulty • Short faulty• Open faulty • Short faultySym

Strona 9

2) At this moment if you take off quick freeze and quick cool button and press refrigerator temp.button (ding-dong sound), it change into the display

Strona 10 - 5-4. Cool Air Circulation

3) Door openwhen door is open, the related display shows an actual temperature.3-1) Display range of freezer is -35˚C~ 30˚Cand refrigerator is -9˚C~9˚

Strona 11

6-1. Power circuit6. Circuit DescriptionsVoltage(DC 12V)Vcc (DC 5V)Circuit usedRelay Operation & LED DisplayPower around MICOM & Sensor Detect

Strona 12

Warning : Please abide by the followingprecautions in order to conductthe maintenance procedures in asafety fashion.1-1. Caution when you replacing co

Strona 13

It is designed for clock generation and timecalculation for synchronizing transmission andreception on the logic elements inside the MICOM.If the X-TA

Strona 14

1) If door is open, door S/W contact is closed. Then MICOM receives “low” signal and detectsdoor open then, Relay control circuit receives “HIGH” sign

Strona 15

At that time, the peak to peak voltage of square signal registers around 12V. The grid #1 ~#5waveforms are as follows.6-6. Button scan and display cir

Strona 16

If MICOM outputs “high” signal to driver-IC(KID65003AP/S1P2655AØ3) according to each loadoperation conditions, IC turns on and DC 12V flows to ground

Strona 17

6-8. Other option functions6-9. Option Table1) Freezer Temperature Shift (Unit ˚C)SHIFTReference-0.5-1.0-2.0-3.0+1.0+2.0+3.0D601----••••D602--••--••D6

Strona 18

7. Trouble shooting1) No power1. Is the power cord well connected to wall outlet?2. Refer to the reference PrecautionsStartYNCheck wiresDC-Trans prima

Strona 19 - 6. Circuit Descriptions

2) Problem with self-test2-1) Problem with outside temperature sensor2-2) Problem with refrigerator temperature sensor26

Strona 20 - 6-4. Door S/W Detector

2-3) Problem in refrigerator defrost sensor2-4) Problem in freezer temperature sensor27

Strona 21 - 6-5. Temperature Sensor

2-5) Problem in freezer defrost sensor28

Strona 22

3) Compressor does not run1. Compressor does not operate in 5 minutes after compressor OFF.2. Compressor does not run during defrosting.3. Compressor

Strona 23 - 6-7. Load Operation

32. Product Specifications3. Electrical part specifications & standardSR-L629EV, SR-L679EV, SR-L627EV, SR-L677EV230-240V50HZMK4A3Q-L1UR600a2GSD(Mi

Strona 24

4) When cooling fan do not activateCheck cooling fan when defrost activation is selected.1. When COMP is OFF both freezer and refrigerator cooling fan

Strona 25 - 7. Trouble shooting

4-2) When refrigerator fan (R-fan) do not activate31

Strona 26 - 2) Problem with self-test

4-3) When COMP cooling fan do not activate32

Strona 27

5) No defrosting1. Even though both F·R-defrost sensors short-circuit, normal operation continues withoutdefrosting.(Refer to self-diagnosis function)

Strona 29 - 3) Compressor does not run

6) When alarm run continuously6-1) If melody alarm runs continuously1. Alarm runs after 2 minute when door is open (melody) and runs in interval in ev

Strona 30

6-2) If Beep sounds continuously6-3) When original panel PCB do not activate36

Strona 31

6-4) When buttons of panel PCB is not selected37

Strona 32

6-5) When the light dosen’t come on in the refrigerator1. Is the power cord well connected to wall outlet?2. Be careful of high-voltage discharge beca

Strona 33 - 5) No defrosting

The connection of DOOR-CABIReference1Inspection of RelayReference2Note) C → Common, NO → Normal open, NC → Normal close3. When it operates as above, i

Strona 34

4ITEM STANDARD6 - 22hr(Vary according to the conditions used)6 - 11hr(Vary according to the conditions used)10 ±2min4hr ±10minTHERMISTOR (502AT), SPEC

Strona 35

SubordinateR Defrost heaterF Defrost heaterCompComp-circulation fanR-Circulation fanF-Circulation fanR-LampF-LampEvaluation of mea-surement resultMeas

Strona 36

(Refrigerator Bulb)1. Open the door and check if the freezer bulbturns on.2. Press the Door S/W and check if the freezerbulb turns off.3. Close the do

Strona 37

Sensor Short : Micom 0V.Sensor Open : Micom 5V.※ Sensor partial pressure resistance 10KΩ* Voltage conversion table depends on H/W structure of MICOM p

Strona 38 - Reference

9. Exploed View9-1. Freezer room 43

Strona 39 - 8. Reference

44NOCODE-NOTRAY-ICE,ASSYTRAY ICE TRAY-FRE UPP,ASSYTRAY-FRE UPP,ASSYTRAY-FRE MID,ASSYTRAY-FRE MID,ASSYTRAY-FRE LOW,ASSYTRAY-FRE LOW,ASSYROLLER FREFIXER

Strona 40

LAMP-FLUORESCENT9-2. Refrigeration room45

Strona 41 - Reference6

46NOCODE-NOCASE-VEG,ASSYCASE-VEG,ASSYCASE-VEGCASE-VEGCOVER-VEGROLLER FREFIXER ROLLERINLAY-COVER VEGCOVER-VEG ASS’YCOVER-VEG ASS’YTRIM-COVER,VEGTRIM-CO

Strona 42

47NOCODE-NO PART NAMESPECOPTIONSR-L627 SR-L629 SR-L677 SR-L679●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●220V~240/50Hz220V/50~60Hz115V~127/60HzCOVER EVAP2

Strona 43 - 9. Exploed View

SR-L627EVSR-L677EV9-3. Door parts48

Strona 44

49NOCODE-NO PART NAMESPECOPTIONSR-L627 SR-L629 SR-L677 SR-L679●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●

Strona 45 - 9-2. Refrigeration room

54. Circuit Diagram4-1. 230V-240V/50Hz, 220v/50Hz,60Hz, 127V/60Hz, 115V/60Hz

Strona 46

50NOCODE-NO PART NAME●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●SPECOPTIONSR-L627 SR-L629 SR-L677 SR-L679●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●

Strona 47

9-4. Cabinet parts & unit51

Strona 48 - 9-3. Door parts

52CODE-NO PART NAME●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●SPECOPTIONSR-L627 SR-L629 SR-L677 SR-L679●●●●●●●●●●●●●●●●●●●●●●●●●

Strona 49

10. Disassembly & Assembly10-1. Replacement of refrigerator lamp1. Remove the cover with the back latch pressed.2. Pull out the lamp.3. After repl

Strona 50

541. Remove the cover by pressing the bottom latch.2. Replace the lamp by turning it counter-clock wise.3. Reassemble the cover in the reverse order o

Strona 51 - 9-4. Cabinet parts & unit

551. Take out food stuffs and trays from refrigerationroom.2. Remove 4 cap screws with (–) driver or similartools.3. Remove 6 screws from the cover-ev

Strona 52

566. Remove the housing of wires.

Strona 53

Cooling cycle unit assembly in the refrigeration compartment Dust assembly in the refrigeration compartment57

Strona 54

581. Take out the case from the freezer.2. Remove 2 screws from the assy-supt free.3. Pull out the holder of the assy-supt free anddisconnect wire ter

Strona 55

596. Remove 2 screws from the back cover of thecooling cycle unit and remove the latch with (–)driver. Assembly of the cooling cycle unit in the freez

Strona 56

6F-ROOM SENSORBLUYELORGPRPGRYBLKBRNWHTS/BLUCN30CN10CN70CN71BLKBLKBLKBLKDC TRANSTHERMAL FUSES/BLURUNNING CAPACITORCOMPRESSORBRNWHTYELGRYW/BLKORGBLUPNKR

Strona 57

601. Remove the screws securing the mechanic compartment cover of the back bottom of the refrigerator.2. Mechanic compartment assembly10-6. Assembly o

Strona 58

611. Disconnect the power cord.TEST S/WCondenserD/C TransPBA-SUB(INVERTER-PCB)3. Assembly specification of electric box2. Remove the cover ofelectrica

Strona 59 - (Coolant & noise

621. With dispenser model.1-1) Press the fixing lever, lift the exclusive watertank upwards, then remove it.1-3) Push the latch of control panel assem

Strona 60

6311. PCB Circuit Diagram

Strona 61 - 10-7. Electric box assembly

3-TERMINAL 1A POSITIVE VOLTAGE REGULATORSThe MC78XX/MC78XXA series of three-terminal positive regulators are available in theTO-220 package and with s

Strona 62

REGULATOR(MC7812C)ELECTRICAL CHARACTERISTICS MC7812(Refer to test circuit, Tmin < Ti < Tmax, Vi = 500mA, Vi = 19V, Ci = 0.33㎌, Co = 1.0㎌ unless

Strona 64 - BLOCK DIAGRAM

67                 

Strona 67

5-1. Product Dimension5. Function & Operating InstructionMODELSR-L679EVSR-L677EVSR-L629EVSR-L627EVA1790179017901790B1013.51013.51013.51013.5C15081

Strona 68

70        

Strona 71 -

73         

Strona 78

85-2. Part Name & Disassembly• Top tray disassemblyPull it forward.Take out food stuffs andpull it out by following thearrow.Take out the water bo

Strona 80

© Samsung Electronics Co., Ltd. November 2001Printed in KoreaCode-No : DA68-01130A REV(0.0)

Strona 81 - Printed in Korea

5-3. Circulation of Refrigerant (H.M CYCLE)Compressor → Sub condenser → Cluster pipe → Hot pipe → Dryer → Capillary tube → R-Evaporator → F-Evaporator