Installing the Air conditioner
Cutting or Extending the Pipe
A 24.6ft(7.5m) pipe is supplied with the air conditioner. (Optional)
The length of the pipe can be:
Extended up to 98.4ft(30m)
Shortened as required
If you need a pipe longer than 24.6ft(7.5m):
You must extend the assembly cable.
You must add refrigerant to the pipes;
otherwise, the indoor unit may freeze.
1 Make sure that you prepared the required tools. (pipe cutter, reamer, flaring
tool and pipe holder)
2 If you want to shorten the pipe, cut it using a pipe cutter ensuring that the cut edge
remains at 90° with the side of the pipe. There are some examples of correctly and
incorrectly cut edges below.
Oblique Rough Burr
3 To prevent a gas leak, remove all burrs at the cut edge of the pipe using a reamer.
4 Put a flare nut slightly into the pipe and modify the flare.
Outer Diameter (D) Depth (A)
inch(
6.35 mm)
inch(
1.3 mm)
inch(
12.70 mm)
inch(
2.0 mm)
inch(
15.88 mm)
inch(
2.2 mm)
5 Check if you flared the pipe correctly. There are some examples of
incorrectly flared pipes below.
Inclined Damaged Surface Cracked Uneven Thickness
6 Align the pipes to connect them easily. Tighten the flare nuts first with your
hands, and then with a torque wrench applying the following torque.
7 For further details on how to connect to the outdoor unit and purge the air,
refer to page 12.
90
O
Ox x x
xxxx
1
4
1
16
1
16
1
8
1
2
5
8
Outer Diameter Torque
inch(6.35 mm) 10.1~12.3ftlb(140~170kgfcm)
inch(12.70 mm) 27.5~30.4ftlb(380~420kgfcm)
inch(15.88 mm) 31.8~34.7ftlb(440~480kgfcm)
1
4
1
2
5
8