Confidential MAX8698C, Rev08
Page 8/47
DO NOT COPY. DO NOT DISTRIBUTE 12/8/2009
PARAMETER CONDITIONS MIN TYP MAX UNIT
Programmable Low Battery
Detect Hysteresis
See the register “ LBHYST in
LBCNFG”
100
200(Default)
300
400
mV
Programmable Low Battery
Detect Threshold
V
IN5
falling (See the register
“ LBTH in LBCNFG”
2.8
2.9
3.0
3.1(Default)
3.2
3.3
3.4
3.5
V
THERMAL SHUTDOWN
Threshold
160
o
C
Hysteresis
15
o
C
REFERENCE
Reference Bypass Output Voltage
-1.5% 1.25 +1.5% V
REF Supply Rejection
2.5V≤IN1≤5.5V, Test
purposes only
0.2 5 mV
LOGIC AND CONTROL INPUTS
Input Low Level
PWRHOLD, SCL, SDA, MR\,
PWRON, JIGON, SET1,
SET2, SET3, PWREN,
2.5V≤V
IN1~6
≤5.5V, Ta=25
o
C
0.4 V
Input High Level
PWRHOLD, SCL, SDA, MR\,
PWRON, JIGON,
SET1,SET2, SET3,
PWREN, 2.5V≤ V
IN1~6
≤5.5V,
Ta=25
o
C
1.4 V
SCL, SDA Input Hysteresis
0.1 V
SRAD Low Level Three state input 0.5 V
SRAD High Level Three state input
V
IN5
-
0.5
V
T
A
= 25°C
-1 1
μA
Logic Input Current
PWRHOLD, SCL, SDA, MR\,
SRAD, SET1, SET2, SET3,
PWREN,
0V<Vin<5.5V
T
A
= 85°C
0.1 uA
SCL, SDA Input capacitance
10 pF
SDA Output Low Voltage
2.6V<= Vin <= 5.5V, Sinking
3mA
0.2 V
ONO\, RSO\, LBO\
Output Low Voltage
Isink = 1mA 0.4 V