Samsung VP-D310 Dokumentacja Strona 272

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 503
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 271
11-272 | OWNER’S GUIDE
MSI Compatibility Reference
MSI Modular Smart Interfaces for MDAQ and DAQ series modules
MDAQ-SUB-
STG-D
MDAQ-SUB-
BRIDGE-D
MDAQ-SUB-
V200-D
DAQP-STG
DAQP-
BRIDGE-A*
DAQP-
BRIDGE-B
DAQP-LV-D
MSI-BR-ACC -- -- -- --
Isotron (constant current powered) adapter for MDAQ-SUB-BRIDGE / -STG modules with DB9 connector Excitation current 4 mA at 21
V, High pass lter 1.5 Hz, BNC connector
Bandwidth and ranges are dened by connected amplier
Automatic identication via TEDS
MSI-BR-V-200 -- -- -- --
200 V input adapter for MDAQ-SUB-BRIDGE / -STG modules with DB9 connector Differential input conguration, BNC connector
Bandwidth and ranges are dened by connected amplier
Automatic identication via TEDS
MSI-BR-RTD -- not needed -- -- --
Pt100, Pt200, Pt500, Pt1000 and Pt2000 adapter for MDAQ-SUB-BRIDGE / -STG modules with DB9 connector
2, 3 and 4 wire connection methods, 5-pin Binder 710 series connector
Automatic identication via TEDS
MSI-BR-CH-50 -- -- -- --
Charge input interface for DAQP-STG and MDAQ-SUB-BRIDGE / -STG with DB9 connector Range up to 50000 pC, AC coupled with
0.07 Hz, BNC signal connection
Max. 100 kHz bandwidth (dependent on the max. bandwidth of the amplier)
Automatic identication via TEDS
MSI-BR-TH-X -- --
Thermocouple type K / J / T adapter for DAQP-BRIDGE-x and MDAQ-SUB-BRIDGE / -STG modules
For use with isolated thermocouple sensors only ! (except in combination with DAQP-STG-D or DAQP-BRIDGE-A*, which are isolated)
High accuracy cold junction reference measurement, 1 m thermo cable with Mini TC connector
Automatic identication via TEDS*
MSI-V-ACC -- -- -- -- --
Isotron (constant current powered) adapter for DAQP-V-D and MDAQ-SUB-V200-D
Excitation current 4 mA at 21 V, High pass lter 1.5 Hz, BNC connector
Bandwidth and ranges are dened by connected amplier
Automatic identication via TEDS
MSI-V-RTD -- -- -- -- --
Pt100, Pt200, Pt500 and Pt1000 adapter for DAQP-V-D and MDAQ-SUB-V200-D
2, 3 and 4 wire connection methods, 5-pin Binder 710 series connector
Automatic identication via TEDS
MSI-V-CH-50 -- -- -- -- --
Charge input interface for DAQP-LV-D and MDAQ-SUB-V200-D
Range up to 50000 pC, AC coupled with 0.07 Hz, BNC signal connection
Max. 100 kHz bandwidth (dependent on the max. bandwidth of the amplier)
Automatic identication via TEDS
* DAQP-BRIDGE-A does not have TEDS, therefore it cannot recognize MSI interfaces
Przeglądanie stron 271
1 2 ... 267 268 269 270 271 272 273 274 275 276 277 ... 502 503

Komentarze do niniejszej Instrukcji

Brak uwag